MSR-Electronic PolyGard® ARB2 Stand-Alone Gas detector
PolyGard® ARB2 is a Stand-Alone type gas detector that senses oxygen, toxic gases, flammable gases, and vapors in spaces without danger of explosion and goes off alarms when it's dangerous.
It is possible to utilize various types of sensors, including EC, CAT, and IR sensors. The device offers outputs such as standard 4-20 mA analog output and relay function. An LCD display inside shows real-time gas concentrations, and it can be connected to sensors installed at distances of up to 500 meters.
Features and Benefits
- EC, CAT, IR sensors
- Standard 4-20mA anlaog output, Relay function
- Self-Test
- Three-color lamps and a buzzer based on device status(Optional)
- Plug-in sensor
- Remote sensor connection (up to 500 meters)
- Use of oxygen sensor up to 7 years
- Convenient maintenance
- Options for AC or DC power
- UL61010, EN50271 Certified
Specification
Category | Description |
---|---|
Size | Type A: 94(W) x 130(H) x 57(D) mm / Type G: 94(W) x 130(H) x 81(D) mm / Type N: 80(W) x 82(H) x 56(D) mm / Sensor: 24(D) x 22(H) mm |
Weight | about 330g |
Material | Polycarbonate |
IP Rating | IP65 |
Welding connector | Type A&G: 2 x M12 or 3 x M20 / Type N: 1 x M20 |
Terminal | Screw type terminal, 0.25 ~ 2.5 mm²(power), 0.25 ~ 1.3 mm²(relay) |
Display | 2 x 16 characters |
Temperature | -30 ~ +60℃(depending on the sensor) |
Humidity | 15 ~ 95%RH(non-condensing) |
Power supply | 24Vdc+/-20%, 185mA or 100-240Vac, Max.5VA |
Buzzer and lamp | 85dB at 0.1m, 3-color LEDs(Option) |
Output | Analog: 4~20mA(3-wire system) / Relay: AL/Fault, 30VAC/DC 2A |
Certificactions | EMC directives 2014/30/EU / CE EN 61010-1:2010 / ANSI/UL 61010-1 / CAN/CSA-C22.2 No. 61010-1 |
MC2 Sensor Specification
Gas | Measuring range | Sensor | Resolution |
---|---|---|---|
CH4 | 0-100 %LEL | IR | 0.1 %LEL |
CH4 | 0-100 %Vol | IR | 0.1 %Vol |
C3H8 | 0-100 %LEL | IR | 0.1 %LEL |
CO2 | 0-5 %Vol | IR | 0.001 %Vol |
CO2 | 0-10 %Vol | IR | 0.01 %Vol |
CO2 | 0-5000 ppm | IR | 1 ppm |
CH4 | 0-100 %LEL | CAT | 0.1 %LEL |
C3H8 | 0-100 %LEL | CAT | 0.1 %LEL |
C3H8 | 0-30 %LEL | CAT | 0.01 %LEL |
C3H8 | 0-5000 ppm | CAT | 1 ppm |
HC | 0-100 %LEL | CAT | 0.1 %LEL |
O2(2, 3year lifespan) | 0-25 %Vol | EC | 0.01 %Vol |
O2(5, 7year lifespan) | 0-25 %Vol | EC | 0.01 %Vol |
CO | 0-150, 250, 300, 500 ppm | EC | 0.1 ppm |
H2S | 0-50 ppm | EC | 0.01 ppm |
H2S | 0-100, 200, 500 ppm | EC | 0.1 ppm |
H2S | 0-1500 ppm | EC | 1 ppm |
NH3 | 0-100, 300, 500 ppm | EC | 0.1 ppm |
NH3 | 0-1000, 5000 ppm | EC | 1 ppm |
NO2 | 0-100 ppm | EC | 0.1 ppm |
HCN | 0-50 ppm | EC | 0.01 ppm |
HCN | 0-100 ppm | EC | 0.1 ppm |
HCl | 0-20 ppm | EC | 0.01 ppm |
Formaldehyde | 0-100 ppm | EC | 0.01 ppm |
Ethylene | 0-200 ppm | EC | 0.1 ppm |
O3 | 0-5 ppm | EC | 0.001 ppm |
O3 | 0-10 ppm | EC | 0.01 ppm |
Cl2 | 0-10, 20 ppm | EC | 0.01 ppm |
SO2 | 0-20 ppm | EC | 0.01 ppm |
Ethylene oxide | 0-10 ppm | EC | 0.01 ppm |