Analytical Industires Inc - GPR Series
Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in their reliability and accuracy.
The Analytical Instruments concepts of using the same HMI and menu structures for portable and online analyzers makes it extremely easy for operators to use both types of instruments on their site without need for extra training.
Features and Benefits
- Rugged design-Proven to last in field operation
- Easy to use
- Up to 30 days on a single charge (40 hours with pump running)
- 0-10 ppm ~ 0-100% O2 Measuring range
- 24 to 32 months sensor life span
- Lightweight – 2.5Kg
- Internal pump option
- 0-1V output
- LT sensor options for CO2 background
Specification
GPR-1100 | GPR-1000 | GPR-2000 | GPR-3500MO | |
---|---|---|---|---|
Measurement Range | 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% | 0-1000 ppm, 0-1%, 0-25% | 0-1%, 0-5%, 0-10%, 0-25% | 0-100% |
Accuracy | < 2% of selected range at constant conditions | |||
Response time(T90) | T90 < 10 seconds | T90 < 13 seconds | ||
Recovery time | 60 sec in air to < 10 ppm in < 1 hour on N2 purge | 60 sec in air to < 100 ppm in < 15 min on N2 purge | NA | |
Sensitivity (LDL) | 0.05 ppm | 5 ppm | 0.005 % | 0.1 % |
Linearity | < 1% of scale | |||
Sensor model | GPR-12-333 | GPR-12-333 | GPR-12-333 | GPR-12-333 |
XLT-12-333 gases containing > 0.5% CO2 |
XLT-12-100-M gases containing > 0.5% CO2 |
XLT-11-24-RTS gases containing > 0.5% CO2 |
||
Sensor life | Within less than 1000 ppm O2 24 months |
GPR-11-32-RTS: 32 months on standby XLT-11-24-RTS: 24 months on standby |
100% O2 within 24 months | |
Calibration interval | 30 days | |||
Inlet pressure | 0.34–2 barg (5-30 psig) with atmospheric vent | |||
Flow rate | 0.5-1.0 L/m (1-2 SCFH) | |||
Gas connections | 1/8" NPT male quick connect | 1/8" quick connect WP 1/8” compression fittings | 1/8" compression tube fittings | 1/4" compression tube fittings |
Wetted parts | Stainless steel |
Brass connections; stainless steel optional |
GP version: stainless steel
fittings; plastic tubing ATEX version: Stainless steel flow housing, tubing and fittings |
Stainless steel |
Display | Graphical LCD 7 x 3.5cm (2.75 x 1.375”) | |||
Resolution | 0.01 ppm | 1 ppm | 0.001 % | 0.1 % |
Enclosure |
Painted aluminum NEMA 4X 10.1 x 22.9 x 7.6cm (4 x 9 x 3”) |
|||
Compensation | Barometric pressure and temperature | |||
Signal output | 0-1 V | |||
LED indication | LOW BATT (72 hrs warning); charging mode | |||
Operating temperature |
5°C to 45°C (41°F to 113°F) (GPR sensor)
-10° to 45°C (14°F to 113°F) (XLT sensor) |
5ºC to 45ºC
(41°F to 113°F) |
||
Power | Rechargeable battery (lead acid) | |||
Battery life | Up to 30 days when fully charged (40 hrs when running pump) | Up to 30 days | ||
Area Classification |
ATEX: Ex ib IIB T4
Tamb +5°C to +45°C |
Multi-purpose only |